Pass or fail, or readings?
HSE says most electrical safety defects can be found by looking, and a pass or fail checker confirms the rest. If someone else needs a certificate with measured values, choose a tester that shows readings.
There are four kinds of PAT tester. Pass or fail checkers suit low-risk offices. Testers with readings show the values a landlord or insurer may want to see. Testers with memory store and download results, and professional testers add 110V and mains tests for contractors and hire firms. Not sure? Answer 3 questions.
We are confirming prices and stock with our suppliers before the shop opens. Answer three quick questions for a recommendation, or ask us and we’ll reply by email with a price.
Four questions decide it. Answer them and the right tester is usually obvious.
HSE says most electrical safety defects can be found by looking, and a pass or fail checker confirms the rest. If someone else needs a certificate with measured values, choose a tester that shows readings.
Battery testers are light and go anywhere, so they suit offices and schools. Mains testers run equipment under load, which adds leakage and power tests, and they usually store thousands of records.
On paper with our free templates, in an app such as Kewtech’s KEWPAT, or stored on the tester and downloaded to a PC. The more items you test, the more a stored record saves you.
Site tools and event kit often run at 110V. Some testers can check them with an adaptor. The Megger PAT420 tests them at 110V directly.
A tester with readings and one-button tests, such as the Seaward PrimeTest 100. It shows the measured value as well as PASS or FAIL, so you learn what good results look like.
A pass or fail checker only tells you whether an item passed. A tester with readings shows the measured values, which a letting agent, insurer or client may want on a certificate.
It is the gentler insulation test used on IT equipment and surge-protected extension leads, which a 500V test could damage or fail wrongly. Every tester we sell has one.
Battery testers are light and work anywhere, which suits in-house testing. Mains testers can run equipment under load for leakage and power tests, and usually store more records.
With some testers. Look for 110V in the chart. Testers marked Partly need an optional adaptor and run fewer tests at 110V. The Megger PAT420 and PAT450 test at 110V directly.
HSE says the person testing must be competent, with the right equipment, the ability to use it and the ability to understand the results. Many people take a short course. Our guide Can I do my own PAT testing? explains what HSE expects.