Can I do my own PAT testing?
Yes, as long as the person doing it is competent. HSE says that in many low-risk workplaces a sensible member of staff with enough knowledge and training can do it, and you don’t need an electrician.
Key facts
- HSE says a competent member of staff can do PAT testing in many low-risk workplaces, and you do not need to be an electrician.
- HSE describes two levels of competence. Pass or fail testers ask the least of you, testers with readings need more knowledge.
- The law does not make PAT testing, or testing every year, a legal requirement in itself.
- Landlords in Scotland must PAT test at least every 5 years and can do it themselves after assessed training.
- Labels and records are not a legal requirement, but they show your scheme exists.
Who can do PAT testing?
Anyone who is competent to do it. HSE says that in many low-risk environments a sensible member of staff can carry out visual inspections if they have enough knowledge and training. Combined inspection and testing needs more knowledge and experience. The person will need the right equipment, the ability to use it properly and the ability to understand the results.
HSE’s fuller guidance, HSG107, goes further and describes two levels of competence for the person doing the testing. The level you need depends on the tester you choose.
| Level | Who it describes | Tester they use | What they need |
|---|---|---|---|
| Level 1 | A person not skilled in electrical work | A simple pass or fail tester, with no readings to interpret | To know how to use the tester correctly, follow set test procedures and work to clearly defined pass criteria |
| Level 2 | A person with appropriate electrical skills | A tester that gives readings which need interpreting | Technical knowledge or experience of this type of work |
This is the most useful thing to know before you buy. A pass or fail tester such as the Seaward PrimeTest 50 asks the least of you. A tester that shows readings, such as the PrimeTest 100, gives you numbers to put on a certificate, and you need to understand what those numbers mean. Knowing why a long extension lead reads high on earth continuity, or why a big urn shows more leakage than a kettle, is where a training course earns its keep.
Competence is also about knowing your limits. HSG107 says trained people should know when the limit of their knowledge and experience has been reached. Anything you are not sure about goes to someone who is.
What the law actually asks for
The Electricity at Work Regulations 1989 require any electrical equipment that could cause injury to be maintained in a safe condition. HSE is clear about what that does and does not mean.
The Regulations do not specify what needs to be done, by whom or how frequently (ie they don’t make inspection or testing of electrical appliances a legal requirement, nor do they make it a legal requirement to undertake this annually).
HSE, PAT FAQs
So you decide, based on risk. A kettle in a staff kitchen and a drill on a building site carry very different risks, so they need checking at different intervals. Our guide to how often PAT testing should be done sets out HSE’s suggested starting points for both.
One more point from HSG107 matters if you are weighing up doing it yourself against paying a contractor. Even if a contractor carries out the maintenance, the duty holder still has overall responsibility for complying with the law. Bringing the testing in-house does not add to your legal duty, and paying someone else does not remove it.
Landlords have their own rules
Rented homes are where the rules differ most, and where most of the confusion sits. Here is what the current government guidance says for England and Scotland.
| Where and who | Do appliances you provide need checking? | How often | Can you do it yourself? |
|---|---|---|---|
| Private landlord in England | Not under the 2020 electrical safety regulations, which cover the fixed wiring. Appliances you supply must still be safe. | No interval set for appliances. The wiring needs an inspection at least every 5 years. | Yes, if you are competent |
| Social landlord in England | Yes, since the 2025 extension of the regulations | At least every 5 years, with an in-service inspection and testing record | The check must be done by a qualified person |
| Private landlord in Scotland | Yes, under the Repairing Standard guidance | Before the first let, then at intervals of no more than 5 years | Yes, after an appropriate assessed training qualification |
In England, the electrical safety standards guidance was updated in November 2025 to bring in the social rented sector. Social landlords must have the electrical equipment they provide checked at least every 5 years and keep an in-service inspection and testing record. For social tenancies granted before 1 December 2025, the first check had to be done before 1 November 2026.
In Scotland, the Repairing Standard guidance sets out five points for landlords.
- Appliances the landlord provides are PAT tested before the property is first let, then at intervals of no more than 5 years.
- A landlord counts as competent once they have passed an appropriate assessed training qualification.
- Appliances bought new less than a year before the test do not need including, but second-hand ones do.
- Tenants’ own appliances are not the landlord’s duty.
- Results go in an equipment register and a combined inspection and test record, which our free templates cover.
Which qualification?
The law does not name one, but most people take the City and Guilds 2377-77 Level 3 Award in the In-service Inspection and Testing of Electrical Equipment. It replaced the older 2377-22 and 2377-32 awards. The Scottish landlord guidance also names the EAL Level 3 Award in the same subject. Either gives you a certificate to show an insurer, a letting agent or an inspector that the person testing is competent.
If you will only use a pass or fail tester on low-risk office kit, HSE’s Level 1 description shows a shorter in-house briefing on the tester and your procedures can be enough. If you will hand out certificates with readings, take the course.
What the IET Code of Practice adds
The IET Code of Practice for In-service Inspection and Testing of Electrical Equipment is the practical rulebook most testers and courses work to. The current 5th edition was published in 2020 and runs to 136 pages. HSE describes the Code as aimed at people contracted to carry out PAT testing, students working towards the qualifications and facility managers, and says it recommends what may be considered pass or fail conditions.
The IET lists these among the changes in the 5th edition.
- Requirements for electrical safety management and guidance on how to carry out a risk assessment
- The testing needed to make sure equipment is safe for continued use, with a new hierarchy of tests
- Changes to the acceptable test result limits
- ES1 and ES2, to reflect changes to product standards, and guidance on the new product classifications
- Updated standard references and revised model forms
Two practical points follow. If you learnt to test on the 4th edition, check that the pass limits set in your tester match the 5th. And when you buy, look for a tester whose maker states it meets the 5th edition. Seaward states this for the PrimeTest 50, 100 and 250+ and the Apollo range, and each of our product pages links to the datasheet that says so.
What you need to do it yourself
- Knowledge. A course in in-service inspection and testing, or equivalent experience, matched to the tester you will use.
- A PAT tester. One that runs the tests your equipment needs. For most offices that means readings and a 250V insulation test for computers and surge-protected leads.
- Pass and fail labels. So people can see at a glance what has been checked.
- A record. What you own, when it was checked and when it is next due. Our free templates cover this.
- A calibrated tester. A calibration certificate shows the tester was reading accurately, which matters the day someone questions a result.
How a test day goes
- List everything that plugs in, room by room, in an appliance register. Include extension leads, kettle leads and chargers, which are easy to miss.
- Look at each item before you test it. HSE says most electrical safety defects can be found by visual examination. Check the plug, the cable, the case and, where the plug can be opened, the fuse, the wiring and the cord grip.
- Decide whether it is Class I (earthed) or Class II (double insulated, marked with a square inside a square). If you can’t see the symbol, HSE says to treat it as Class I.
- Run the tests that match. A Class I item gets an earth continuity test, which proves the metal case is connected to earth, and an insulation test. A Class II item gets an insulation test only. Use 250V rather than 500V for computers and anything with surge protection, so the test does not trip the protection and give a false fail.
- On a tester that has one, run the leakage test, which shows how much current would escape through a person touching the item.
- For leads, test earth continuity, insulation and polarity, so you know live and neutral are not crossed.
- Label it pass or fail, take any failed item out of use straight away and record every result.
HSG107 adds what the inspection alongside a test should cover. That means the correct polarity, the correct fuse, cables and cores properly terminated, and whether the equipment suits the place it is used.
How a primary school with 180 items plans its first year
The school business manager lists 180 items. There are 40 earthed items such as kettles, the staffroom microwave and the irons in the design and technology room, 95 double-insulated items such as laptop chargers, lamps and the classroom speakers, 30 extension leads and 15 desktop computers bought last year.
Using HSE’s low-risk table as a starting point, the 40 earthed items and 30 extension leads get a full PAT test. The 95 double-insulated items get a formal visual inspection, and the hand-held ones are looked at by staff before use. The desktop computers are earthed, so HSE suggests a combined test up to every 5 years and a visual inspection every 2 to 4 years. They are a year old, so they are not due. That makes 70 items to test in year one, not 180. Because it is the school’s first year of in-house testing, HSG107’s advice is to test anything that has been in use longer than its interval without ever being tested, so this first round covers all 40 earthed appliances and 30 leads, whatever their age. The computers join the test list once they reach their interval.
HSG107 also notes that schools often need more than one regime, so the kitchen, where use is heavier, may be checked more often than the classrooms.
When to call someone in
Doing your own testing covers most of what an office, school or landlord owns. Some things still belong with a specialist.
- Large items wired in rather than plugged in, such as water boilers. HSE says these come under maintenance of the fixed installation, not PAT.
- Medical electrical equipment, which HSG107 places outside its scope because it has special requirements.
- Three-phase and high-current equipment, unless your tester and training cover it.
- Any result you can’t explain. A competent tester stops and asks rather than passing an item they are unsure of.
When doing it yourself makes sense
Doing your own testing works best when you have a steady number of items, the same people looking after them and somewhere to keep the records. Schools, offices, care homes, landlords with several lets and event companies with their own kit are typical. You choose the day, test new arrivals as they come in and keep the history in one place. If you have a few items once every few years, paying a local tester may be simpler.
Questions people ask
Can’t see your question here?
Do I need an electrician to do PAT testing?
No. HSE says the person doing it needs to be competent, not an electrician. For combined inspection and testing they need the right equipment, the ability to use it properly and the ability to understand the results.
Is PAT testing a legal requirement?
Not in itself. The Electricity at Work Regulations 1989 require electrical equipment that could cause injury to be kept safe, but HSE says they do not make inspection or testing a legal requirement, or say it must be done every year.
Do I need a qualification?
The law does not name one. The usual course is the City and Guilds 2377-77 Level 3 Award in the In-service Inspection and Testing of Electrical Equipment, which replaced the older 2377-22 and 2377-32. Your insurer may have its own view, so it is worth asking.
Can a landlord do their own PAT testing?
In Scotland, yes, once you have passed an appropriate assessed training qualification, according to the Repairing Standard guidance. Private landlords in England are not required to PAT test by the 2020 regulations. Social landlords in England must have equipment they provide checked by a qualified person at least every 5 years.
Do I need to label and record everything?
There is no legal requirement to do either, according to HSE. Labels and records are still a useful way to show a scheme exists, and most insurers and letting agents expect them.
Does a repaired appliance need testing?
Yes. HSE’s guidance HSG107 says a combined inspection and test is likely to be justified after any repair, modification or similar work, including a new plug.
Does new equipment need testing?
HSE says new equipment should be supplied safe and should not need a formal test, but a simple visual check is recommended to make sure it is not damaged.